INNOVA® E3 CMS – The entry-level AER for leading hygienic single channel monitoring

With our patented CMS individual channel monitoring for the reprocessing of two flexible endoscopes, we provide the highest hygiene standards in a compact AER. Like its larger siblings, the INNOVA®E4 CMS and INNOVA®E5 CMS, the AER is also able to detect partial contamination in the endoscope channels and thereby raises your patient safety to a new level. 

The BHT machine can, if desired, be delivered as a space-saving under-counter model or ergonomic floor-standing model. These features make the AER the perfect solution for the increasing demands of practices and clinics.


  • 2 flexible endoscopes and/or 4 ENT per reprocessing.
  • For 10 to 20 endoscope reprocessing procedures daily.
  • With patented CMS (Channel Monitoring System) flow control.

Hygiene, reliabilty and efficiency in endoscope reprocessing

  • Unbeatable cleanliness and hygiene in each cycle


    • The patented CMS system (Flow Control) for the highest precision of flow control.
    • Compliant with DIN EN 15883-1/-4 standards and RKI guidelines.
    • Thermal disinfection of the rinse water in line with RKI recommendations (in the DH type).
  • Stable processes each day and for years to come


    • Continuous process support thanks to extensive online support: Up to 70% fewer service calls due to remote maintenance access. 
    • Traceability using batch control: Data output via data logger, printer or computer interface.
    • The device is based on the INNOVA® E3 , the bestselling BHT machine in the world: it has proven itself 1,000 times over! 
  • Efficient processes for your endoscope reprocessing


    • Each AER is optimised for short cycle times whilst ensuring a RKI-compliant reprocessing of your washing goods.
    • Low total cost of ownership: Due to the free choice of process chemicals, no expensive filters and low media consumption.
    • Option: The machine comes as an under-counter model or as a free-standing model with cover plate for additional storage.

INNOVA®E3 CMS at a glance

Product features

  • Complies withDIN EN 15883-1/-4 standards and RKI guidelines (e.g. by thermal disinfection of the final rinse water in machines with boilers)
  • Can be flexibly deployed alongside another INNOVA® E3 CMS to accommodate 30 to 40 reprocessing procedures daily.
  • Patented CMS System (Flow Control) for the highest patient safety in the long-term.
  • Open chemical systems:  Operates with glutaraldehyde and peracetic acid which can be purchased from numerous providers.
  • The AER is ideal for all conventional endoscopes from Fuji, Olympus, Pentax, Storz, Wolf, etc.*.
  • Leak test throughout the entire reprocessing programme for careful reprocessing.
  • Secure traceability in each cycle via the documentation of the individual process parameters.
  • Simple integration into a wide range of hospital systems and tracking software. Transfer of endoscope and process parameters possible.
*Please note the manufacturer information on the mechanical reprocessing of your instruments

Technical data

Capacity For 2 flexible endoscopes*:
For up to 20 endoscopes reprocessings per day
Under counter model (W/D/H) 1200 x 680 x 850 mm; with cover plate H: 880 mm
Free-standing model (W/D/H) 1000 x 800 x 1440 mm
Washing chamber (W/D/H) 540 x 535 x 510 mm
Hygiene concept Hygienic workflow, 1-door, CMS cleaning standard
Single channel monitoring (CMS) Yes, patented solution with maximum measuring accuracy
Process chemistry Glutaraldehyde or peracetic acid possible
Documentation and Integration Scanner, EDP interface integrated. Printer possible. Connection to existing hospital systems
Electrical Installation 3 ph 400 V / 50 Hz AC+N+PE. Connected value: 11 KW. Fuse protection: 3×20 A
Water Connections Cold, warm, and demineralised water; for the DC version, additional mixing water (30°C to 40°C, chemistry adjustable) is recommended for acceleration; DN 20 in each case; 2-5 bar flow pressure; waste water DN 50
*Please note the manufacturer information on the mechanical reprocessing of your instruments

Brochure Download

The INNOVA® E series for endoscope reprocessing